Bug 134173

Summary: Temperature actions written with wrong configuration variables in scheme config
Product: [openSUSE] SUSE Linux 10.1 Reporter: Holger Macht <hmacht>
Component: YaST2Assignee: Jiri Srain <jsrain>
Status: RESOLVED FIXED QA Contact: Klaus Kämpf <kkaempf>
Severity: Normal    
Priority: P5 - None    
Version: Alpha 3   
Target Milestone: ---   
Hardware: Other   
OS: Other   
Whiteboard:
Found By: Other Services Priority:
Business Priority: Blocker: ---
Marketing QA Status: --- IT Deployment: ---

Description Holger Macht 2005-11-17 13:38:42 UTC
When editing the default actions for "Overheat Temperature Action" and "Critical Temperature Action", the written config variables to a scheme config file (e.g. /etc/sysconfig/powersave/scheme_powersave) are wrong:

  THERMAL_CRITICAL=""
  THERMAL_HOT_ACTION=""

These must be (like in /etc/sysconfig/powersave/events)

  EVENT_TEMPERATURE_CRITICAL=""
  EVENT_TEMPERATURE_HOT=""

I don't know whether they were renamed some time ago or it never worked. But until know, nobody noticed ;-)
Comment 1 Jiri Srain 2005-12-02 09:48:24 UTC
Fixed in SVN for 10.1.