Bugzilla – Full Text Bug Listing |
| Summary: | ifplugd controlled device doesn't go down with "ifdown ethX" | ||
|---|---|---|---|
| Product: | [openSUSE] SUSE Linux 10.1 | Reporter: | Dirk Mueller <dmueller> |
| Component: | Network | Assignee: | Christian Zoz <zoz> |
| Status: | VERIFIED FIXED | QA Contact: | E-mail List <qa-bugs> |
| Severity: | Normal | ||
| Priority: | P5 - None | CC: | suse-beta |
| Version: | Beta 4 | ||
| Target Milestone: | --- | ||
| Hardware: | Other | ||
| OS: | Other | ||
| Whiteboard: | |||
| Found By: | Other | Services Priority: | |
| Business Priority: | Blocker: | --- | |
| Marketing QA Status: | --- | IT Deployment: | --- |
|
Description
Dirk Mueller
2006-02-22 15:59:52 UTC
It remains up and ifplugd keeps running, but the v4 addresses are flushed. If you want to put it down completely you have to call 'ifdown <iface> -o rc' or rcnetwork stop <iface>. I'm not sure if i can change this by now. I'll have a look. Its a change from previous behaviour, not sure if it was an intended change. No, there was no change. ifdown <iface> without options did never take down an interface completely which has STARTMODE=ifplugd. Dirk, please try sysconfig from mbuild/oran-zoz-19. |