Description Forgotten User 6xye-mzk9k 2010-08-23 11:38:13 UTC
User-Agent:       Mozilla/5.0 (X11; Linux x86_64; rv:2.0b3) Gecko/20100805 SUSE/4.0b-4.1 Firefox/4.0b3

Systray misbehave after plasma-desktop restarted.

Reproducible: Always

Steps to Reproduce:
1. kquitapp plasma-desktop 
2. plasma-desktop
3. mouse right button click on Klipper icon in tray
Actual Results:  
plasma-desktop(15487)/plasma StatusNotifierItemSource::refreshCallback: DBusMenu disabled for this application
plasma-desktop: symbol lookup error: /usr/lib/kde4/plasma_engine_statusnotifieritem.so: undefined symbol: _ZN16DBusMenuImporter10updateMenuEv

Expected Results:  
normal behavior

KDE developer says its specific distro compilation problem.
http://forum.kde.org/viewtopic.php?f=66&t=89668

only kdebase4-workspace 4.5.0.-493.3 affected.
Comment 1 Christian Trippe 2010-08-24 17:42:22 UTC
I cannot reproduce this. Please make sure that you really have a consitent installation, e.g. try 'zypper dup --from YourKDEDistroFactoryAlias'
Comment 2 Forgotten User 6xye-mzk9k 2010-09-01 05:59:43 UTC
Bug doesn't appear after 4.5.1 upgrade.
Please close ticket.
Comment 3 Christian Trippe 2010-09-01 08:26:05 UTC
Fixed