Bug 113644 - Minor stuffs for KPowerSave after your call for testing
Summary: Minor stuffs for KPowerSave after your call for testing
Status: VERIFIED FIXED
Alias: None
Product: SUSE LINUX 10.0
Classification: openSUSE
Component: Mobile Devices (show other bugs)
Version: Beta 3
Hardware: i686 SUSE Other
: P5 - None : Minor
Target Milestone: ---
Assignee: Danny Kukawka
QA Contact: E-mail List
URL:
Whiteboard:
Keywords:
Depends on:
Blocks:
 
Reported: 2005-08-28 15:35 UTC by Florent CHANTRET
Modified: 2007-06-05 11:04 UTC (History)
2 users (show)

See Also:
Found By: Other
Services Priority:
Business Priority:
Blocker: ---
Marketing QA Status: ---
IT Deployment: ---


Attachments

Note You need to log in before you can comment on or make changes to this bug.
Description Florent CHANTRET 2005-08-28 15:35:51 UTC
Hi,

I've tried KPowerSave.

It works perfectly when I plug or unplug the AC adaptater. The icon is very
responsive. The battery level is correctly displayed.

Minors bugs are :

- When I unplug the AC adaptater, the icon tell me there is about 12 or 13 hours
remaining (quite nice for a Centrino ;o)). The icon is correcly updated to about
2 hours and a half remaining after about 10 or 20 seconds. It is the same in
SuSE 9.3 I think

- The tooltip doesn't give the CPU frequency as it was the case on SuSE 9.3
Comment 1 Danny Al-Gaaf 2005-08-29 08:17:58 UTC
> - The tooltip doesn't give the CPU frequency as it was the case on SuSE 9.3
Fixed for Beta 4

> When I unplug the AC adaptater, the icon tell me there is about 12 or 13 hours
remaining (quite nice for a Centrino ;o)). The icon is correcly updated to about
2 hours and a half remaining after about 10 or 20 seconds. It is the same in
SuSE 9.3 I think

I think this can happen while calculate the time. Please attach output of 'cat /
proc/acpi/battery/*/*' directly after unplug the adapter.
Comment 2 Florent CHANTRET 2005-08-29 17:30:06 UTC
Here it is :

alarm:                   unsupported
present:                 yes
design capacity:         65120 mWh
last full capacity:      59200 mWh
battery technology:      rechargeable
design voltage:          14800 mV
design capacity warning: 5934 mWh
design capacity low:     0 mWh
capacity granularity 1:  592 mWh
capacity granularity 2:  592 mWh
model number:             LI4403A
serial number:           W810
battery type:            4C 69 00 00 00
OEM info:                 ARIMA
present:                 yes
capacity state:          ok
charging state:          discharging
present rate:            4440 mW
remaining capacity:      59214 mWh
present voltage:         16672 mV
Comment 3 Danny Al-Gaaf 2005-08-29 19:06:44 UTC
Your battery/bios reports a really low present rate. As you say only in the 
first time. This is a hardware/bios problem. Other machines say "unknown" since 
they know well values. Powersave/KPowersave can't know anything about this.

If you now calculate the time 59200 mWh/4440 mW you get 13,3 hours ;)

Thanks for the information, I close the bug now