iSCSI BFS failure on SLES15 SP6 in single path configuraion
Last modified: 2024-05-24 08:24:47 UTC
Dup of 1224134, for HPE kernel issue tracking. Issue: iSCSI BFS failure on SLES15 SP6 in single path configuraion OS: SLES 15 SP6 Public RC How reproducible: Always 100% Steps to reproduce: 1. Configure Marvell Netxtreme2 adapter for iSCSI boot with single path config. 2. Perform SLES 15 SP6 Public RC OS installation on iSCSI LUN. 3. OS installation is successful 4. The first boot failure is observed post switch root phase, [ 334.274558][ T1905] br1: port 1(eth1) entered forwarding state [FAILED] Failed to start iSCSI UserSpace I/O driver. [ 470.796677][ T235] session1: session recovery timed out after 120 secs [ 470.803518][ T539] sd 0:0:0:0: rejecting I/O to offline device [ 470.809491][ T539] I/O error, dev sdb, sector 7673224 op 0x0:(READ) flags 0x80700 phys_seg 3 prio class 2 [ 470.819214][ T539] I/O error, dev sdb, sector 1397376 op 0x0:(READ) flags 0x1000 phys_seg 4 prio class 2 Expected Results: OS boots successfully with single path config Actual Results: OS boot fails as iscsiuio service fails to start Additional info: MPIO config works without any issues