According to bug 559697 comment 37, several Brother scanner USB IDs are missing in the /etc/udev/rules.d/55-libsane.rules. The fix seems to be trivial. The problem probably affects older products that support these scanners (11.1, SLED11) and should be fixed upstream as well.
The content in /etc/udev/rules.d/55-libsane.rules is what the upstream project SANE provides at http://www.sane-project.org/ To get more USB scanners added there, the particular user who has such a scanner should post a mail on the sane-devel@lists.alioth.debian.org list with his snippet in libsane.rules which he added. Furthermore Brother's instructions at http://welcome.solutions.brother.com/bsc/public_s/id/linux/en/instruction_scn1c.html are insecure because the USB model ID is missing, see http://lists.opensuse.org/opensuse-de/2009-11/msg01623.html (German only). Therefore I will not add such kind of insecure stuff. Ahh! For openSUSE11.2 there is no longer a useless GROUP="scanner" but now it is GROUP="lp" which is one step forward but the USB model ID is still missing. I will add a comment to bug 559697.
in the bug report comment I have wrotten IIf uou open this web page http://welcome.solutions.brother.com/bsc/public_s/id/linux/en/faq_scn.html and yoy select When scanning I receive the error "Error during device I/O". you find this page "# When scanning I receive the error "Error during device I/O". The Brother Linux scanner driver works only with a superuser by default. To use it with a normal user, you will have to make some settings. Setting for normal users " setting for normal user give "openSUSE11.2 1. Open "/etc/udev/rules.d/55-libsane.rules" 2. Add the following 2 lines at the last of the device entry. (just before "# The following rule...") # Brother ATTR{idVendor}=="04f9", MODE="0664", GROUP="lp", ENV{libsane_matched}="yes" 3. Restart the OS. page top openSUSE 11.1 1. Open "/etc/udev/rules.d/55-libsane.rules" 2. Add 2 lines for Brother products. The lines to be added--------------------------------- #Brother ATTR{idVendor}=="04f9", MODE="0666", GROUP="scanner", ENV{libsane_matched}="yes"" it is different for suse 11.1 and suse 11.2 during my instal this information was not updated and i have modified like for suse 11.1 now I modified 55 libsane rules and I get the same problem I observe that mode is 664 and every where "mode 664" ha to bee replace by "mode 666" I wil try to replace 664 by 666 and will give the result In fact with 664 or 666 it is the same problem , but about the suggestion of brother what is true ?????? for your information ,as it is suggested i have send a mail to sane-devel@lists.alioth.debian.org list Thanks
Short translation of what I wrote in http://lists.opensuse.org/opensuse-de/2009-11/msg01623.html GROUP="scanner" is useless because there is no such group in openSUSE and it is meaningless when MODE="0666" allows access for arbitrary users. Only {idVendor}=="04f9" (without specific {idProduct}=="...") is insecure because together with MODE="0666" it allows access to any kind of Brother USB devices for arbitrary users. If there exist Brother USB keyboards and/or Brother USB mass storage devices (including e.g. cameras), arbitrary users could sniff anything which is typed in on any Brother USB keyboard (e.g. passwords) and/or read any possibly secret file on any Brother USB mass storage device.
Thanks for all the comments , I have studied them I have understood that when brother give the solution to add the 2 lines " ATTR{idVendor}=="04f9", MODE="0666", GROUP="scanner", ENV{libsane_matched}="yes"" " it is dangerous because theri now id products but I use it with suse 11 11.0 wihout any problem , becase, perhaps I have not device Broyher exeptly my scaner But I am not sure to get this id I send a mai to sane-devel@lists.alioth.debian.org I got this answer "Your mail to 'sane-devel' with the subject Addition of dcp7030 Brother printer end scaner device Is being held until the list moderator can review it for approval. The reason it is being held: Post by non-member to a members-only list" I have also visited sane site , but I was suprised to discover that that Brother's scaners are not in the positiv list